Haas & Sons provides electrical services that includes electrical repair and installations for Clarksville, MD residents —from lighting fixtures to ceiling fan installation to breaker box replacement and surge protection. Call us now at: (443) 396-2555 and see why your neighbors rely on us to deliver local electrical services at great value for a fair price in Clarksville, MD below.
Recent Jobs and Reviews in Clarksville, MD
Clarksville, MD at a glance
Haas & Sons Electric Inc. has completed 22 jobs in Clarksville, MD between May 2019 and February 2022.
The most recent job was on February 23, 2022.
Haas & Sons Electric Inc. has completed 13 jobs in Clarksville, MD in the last 12 months. The first job there was in May 2019.
Job Locations and Reviews
Customer had a gfci circuit that was out due to a power outage I found the customer had multiple gfcis on this circuit and they were line sided and load sided. So when the power went out you had to find the correct sequence of gfcis to reset to get them all back online So I removed all the receptacle devices in all bathrooms one in garage and 3 outside and then spliced all the appropriate wires together and pig tailed off the splice then installed tamper resistant GFCIs inside and line sided the wires. Then I went outside and installed weather resistant GFCIs and in use bubble covers in all locations and siliconed around the boxes to protect the devices from wether elements as much as possible. With line siding the devices, if a device fails it will not affect the other devices on the circuit Customer has a 1 year warranty
Replaced garage 3 button touch switch. All 3 are now working properly.
This estimate includes the installation of a new switch in the family room. In addition we shall repair the poor terminations in 2 nearby receptacles. We have replaced the damaged switch controlling the fireplace blower motor where the power loss stemmed from. In addition we have repaired the splicing in the 2 receptacles nearest to the fire place. Lastly power has been restored and fireplace now working.
This estimate includes the alleviation of all double tapped neutrals in main service panel. We have alleviated all double tapped neutral wires in the main service panel.
The 2 lights closet to the driveway entrance from the street were not working when the others are turned on. I found that the wire was severed somewhere between the last working light and the one closet to that light that is not working. Upon further inspection I found that the wire was cut inside the pipe running into the junction box under the light. I repaired wires with an underground splice kit and put all new splices on wires. Lights are now all working properly.
Remove 3 pendant lights and install 2 new customer supplied lights and cap the 3rd box. Remove breakfast light and cap off box and install 4 recess wafers in room on dimmer. Install a whole home surge protector in electric panel. Verified proper operation of all completed work. Customer does not wish to do powder room light at this time.
We have installed a new dedicated circuit for the sump pump. This circuit is complete with arc-fault protection and GFCI protection. In addition we have ensured that the Verizon equipment now has uninterrupted power. Three way switch leading to basement has also been replaced. However, we recommend that the sump pump be inspected by a qualified plumber.
Removed and replaced gfci in the garage by the garage doors that was switch controlled (switch was by the main front door) this gfci controlled the lamp post out front 30 day warranty
Customers backyard lights and outlets stopped working after i replaced the main panel. While changing the panel customer stated that the lines for the pool were no longer needed since the pool was removed. I traced out the line and found that one of the old pool lines actually now powered all the yard lights and plugs. I reconnected the line and everything powered back up.
Work that was completed is as follows. - installed 4 recess wafers in front room on main level with dimmer - installed 4 recess wafers in rear room on main level with dimmer - removed and replaced foyer light in a 2 story ceiling(new light provided by customer) - removed and replaced dining light and installed a dimmer(customer provided light) - removed and replaced 3 ceiling fans with customer provided fans in 3 bedrooms - made code corrections in panel(breakers and neutrals) - hid surround sound speaker wire in basement and installed a blank plate over opening Verified proper operation of all completed work with customer and verified proper height of hanging fixtures.
Installed new pendant light over island in place of existing recessed light. I added a switch to control new fixture separately from kitchen lights. I removed existing single gang switch that controlled kitchen recessed lights and installed 3-gang box so that new switch could go into it as well as a 4 way for the kitchen dinette light. I tapped 4-way out of the switch at the bottom of the stairs and ran wire in the basement drop ceiling.
Installed new light over kitchen island and installed larger switch bank for new switch locations.
Replacing old smoke detectors with new sealed units with 10 year lithium ion back up batteries and replacing older hanging fixtures with modern style lights.
Replaced broken switches in home. Devices were backstabbed and caused lights to not turn on
Removed existing faulty smoke detector units and installed all new ones in their place. We installed smoke/ carbon monoxide detectors in the hallways and standard smoke detectors in the bedrooms. All new units that were installed have 10 year lithium ion back up batteries.
Fixed wire issue in post
Install LED lamps In Outdoor fixtures and checking GFCI