Haas & Sons provides electrical services that includes electrical repair and installations for Edgewater, MD residents —from lighting fixtures to ceiling fan installation to breaker box replacement and surge protection.
Call us now at: (443) 396-2555 and see why your neighbors rely on us to deliver local electrical services at great value for a fair price in Edgewater, MD below.
Recent Jobs and Reviews in Edgewater, MD
Edgewater, MD at a glance
Haas & Sons Electric Inc. has completed 25 jobs in Edgewater, MD between November 2020 and November 2022.
The most recent job was on November 3, 2022.
Haas & Sons Electric Inc. has completed 20 jobs in Edgewater, MD in the last 12 months. The first job there was in June 2019.
Job Locations and Reviews
Initial reasoning for call was to repair power loss to the front bathroom vanity light. Upon my inspection of the power loss I found that there was a dimmer switch controlling the vanity light. I then found that it was wired incorrectly causing it to burn up. I replaced the burnt up switch with a new standard switch. The vanity light/switch is now properly wired and working correctly. While on site customer also stated the light in her laundry/panel room was not working. I found that the switch next to the fridge was broken. I replaced this switch as well and light is back up and running. I inspected the main panel and found that the home has been rewired in 2004 as well as a 200 amp panel install with a generator sub panel. Panel is in excellent condition with plenty of space. Home has proper GFCI protection in required locations.
-install new weather resistant receptacles with heavy duty in-use covers to replace the outside receptacles. -install new GFCI receptacle in the garage on the back wall. -silicone and seal front outside light along with front and back gfci receptacles.
I added a new receptacle where the customer plans to mount a TV on the wall in the basement it is part of a 20 amp circuit and then I spliced all the appropriate wires together in the existing box and installed a new temper resistant receptacle in the existing box as the old receptacle looked damaged and I installed a tamper resistant receptacle for the TV will be I also installed cable ends in the garage where existing coax cables
We have installed a new customer supplied ceiling fan in the master bedroom. In addition we have replaced the bedroom circuit receptacles and several switches on the second floor associated with the bedroom receptacles. Lastly we have installed a new Arc fault breaker to operate the bedroom circuit.
Original call was to demo a ceiling fan and replace a closet switch. Fan was demoed on back porch due to water entering the fixture. We demoed and customer shall call a roofing expert to determine source of leak. In addition we have replaced the damaged closet switch in the master bedroom.
We had to re wire the upstairs and downstairs switches in order to get two occupancy sensors to work together. Essentially making them into single pole switches that overriding one another. We tested the switches multiple times and they work. This was a call back so we only charged for the second switch
I took down both fans in sun room and re wired them then added two fan control switches I added a motion sensor in downstairs stair way I added a outlet in the laundry room I removed and replaced a light in master closet I removed and replaced a ceiling fan in living room Replaced three way switch at top of stairs from basement to first floor Replaced receptacle in laundry room Customer has a 30 day warranty
We have installed 3 customer supplied ceiling fans. Locations are master bedroom, living room and rear porch. In addition we have installed a spare breaker and have removed ground wires from the neutral bar.
Customer lost power to invisible fence on the exterior of the home. Gfci was tripped. GFCI was reset and it powered right up.
I removed a damaged well light and took the jumper wires and put them in a underground splice kit then covered the hole back up I removed two damaged spot lights by the flag pole and put knockout seals back in the weather proof boxes 30 day warranty
This estimate includes the install of 3 switches. 1 customer supplied and 2 supplied by Haas and Sons. We have installed the switches in the kitchen and hallway.
This estimate includes the installation of a new 4inch LED recess light in the kitchen area. We have replaced the existing damaged recess light in the kitchen area.
I removed and replaced two indoor light fixtures one laundry room and one pantry I removed and replaced two outside lights with motion lights We will need to return to remove and replace the other three motion lights around the house and on the roof due to poor weather I returned and installed 3 customer supplied motion lights I also installed a siding block on a light I did last time I was here to protect the inside of the box better. I removed a light and installed a weather proof blank plate
Outlets on pier were completely submerged on the last large storm. This caused the GFCI outlet closet to the house to short out. I removed the 2 original outlets and installed new weatherproof boxes at the top of the pylons with the lift motors and installed new weatherproof outlets with in-use covers. I ran a new 12/2 UF wire from the 1st outlet to the 2nd one. I removed the standard breaker and installed a dual function CH breaker to protect circuit. Once completed i turned everything on and it all worked properly.
Removed and replaced multiple customer supplied wall sconces outside around the home Removed and replaced 4 company supplied led high powered motion lights around home Two lights in front of the home were not replaced but need to be RE-fed due to a burnt switch leg Customer has 1 year. Warranty on work preformed I installed 2 light fixtures outside by the front door. I had to re feed the jumper between the two lights though the inside door way as the one on the left was burnt and broken. I installed two new siding blocks because the existing switch leg did not come through a box for support
I isolated the circuit going from the side of the house out to a patio shed that use to have a hot tub in it. I also found the circuit feeding a disconnect for the hot tub. I turned off power to both then removed the disconnect and sealed the hole the wires were coming through the side of the home. I then cut the 14-2 UF cable feeding the receptacles in the patio then ran a piece of pvc up the wall on the side of the home and installed a weather proof box over the sealed hole the hot tub wires were coming through I then installed a weather resistant tamper resistant gfci and a in use bubble cover and then siliconed around the weather proof box. Then I removed the wires from the main electrical panel that powered the hot tub so there is no way they could ever be energized. Tuned the breaker back on for the gfci and tested it. I also demoed all the wires and devices in the patio area so the customers would feel safe working in there Customer has a 6 month warranty for all work preform
We have provided Gfci protection for the kitchen receptacles. In addition we have replaced the basement stairwell switch, and rear exterior receptacle and have identified the rear exterior post light power source, bypassing the photo cell.
Installed new 50 amp dedicated circuit for Tesla car charger. We installed a new flush mounted NEMA 14-50 outlet directly below the panel in the garage. We also installed a new 50 amp 240volt Square D QO series breaker to control the new circuit. We also replaced a broken outlet on back porch as a thank you for using us.
We have installed the new porch light on 1720 shore dr. In addition we have replaced the damaged recess trim.
Installed a new 100 amp square d qo panel in place of old panel. All breakers are new as well as a whole home surge protector. Customer did not want to do a upgrade to 200 amp due to having to relocate the panel for inspection and replacing the service mast. Service cable is in good shape so decided to just install a new panel.
Replaced hallway bathroom exhaust fan with a new Panasonic quiet type fan. I reconnected existing venting and wired to original switch. Fan in working perfectly.
Installed 5 gfcis in the following locations. -2 in the master bathroom receptacles on either side of mirror. -1 in guest bathroom downstairs -1 in second guest bath downstairs - 1 on washer receptacle downstairs. Also added a receptacle in guest bedroom closet downstairs using existing receptacle on other side of wall. No drywall repair is required for work performed. Verified proper operation of completed work.
Went through electrical system. And found no issues. It’s my belief it’s either the transformer or the overhead service is at fault. Call bge tell them a licensed electrician did a assessment on electrical system and found no faults on our end Installed a ultra surge protector to help protect the houses utilities and electrical system
We have troubleshot and repaired loss of power to guest bedroom and upstairs office area. Circuit fed from guest bedroom, then to hallway and bathroom, terminating finally in office upstairs.
Installed new customer supplied sconces and chandeliers in home.