Haas & Sons provides electrical services that includes electrical repair and installations for Elkridge, MD residents and businesses—from lighting fixtures to ceiling fan installation to breaker box replacement and surge protection.
Call us now at: (443) 396-2555 and see why your neighbors rely on us to deliver local electrical services at great value for a fair price in Elkridge, MD below.
Recent Jobs and Reviews in Elkridge, MD
Job Locations and Reviews
dennis@haasandsons.com
Installation of new light fixture located in 1st floor bathroom. Currently fixture is creating a light flicker due to age of it and wiring going bad.
Elkridge, MD 21075
Nicholas T.
Replace bad receptacle on the left wall in the second floor front bedroom.
Elkridge, MD 21075
Nicholas T.
Install New dedicated up circuit next to main panel located in the garage. Install new GFCI breaker and 50 amp charging 1450 receptacle.
Elkridge, MD 21075
dennis@haasandsons.com
Replacement of two smoke detectors and one combination detector. Replacement necessary due to previous detectors failing. Additionally, replacement of a AFCI breaker inside the panel that is not properly tripping when tested. Replacement of a 15 amp breaker due to circuit having a shared neutral and not having a common trip handle. Installation of new whole home surge protector to further assist the home in protection of voltage spikes while protecting home appliances. Surge is a 120kA with lifetime replacement.
Elkridge, MD 21075
dennis@haasandsons.com
Replacement of the drier cord due to device not having proper connection with 3 prong appliance cord and 4 prong appliance receptacle. Installation of new outlet for appliance on side of home coming out of pre-existing outlet.
Elkridge, MD 21075
Review
Nicholas T.
We will replace weather resistant receptacle at pool pump. We will replace GFCI on the back of the Home, but they weather resistant GFCI a new in use cover
Elkridge, MD 21075
Alex W.
I installed a 2 piece siding block and installed a customer supplied light I installed a high powered doorbell transformer and a customer supplied ring doorbell I also performed a annual assessment and went over everything with the customer
Elkridge, MD 21075
Genny G.
Today’s visit was for EV charger receptacle overheating. During assessment, we did notice discoloration on the receptacle. Voltage reading in the panel at the breaker, and on the receptacle itself was proper voltage. The receptacle that it was connected to was a standard range receptacle, so we replaced it with an EV charger rated receptacle. Please let us know if you have any questions. Have a great day!
Elkridge, MD 21075
Nicholas T.
We will replace all 3 exterior and as well as the bathroom receptacles with new GFCIS. We will install all new in-use covers on exterior GFCIS.
Elkridge, MD 21075
dennis@haasandsons.com
Installation of new 200 amp panel to replace current outdated Sylvania panel that has multiple hazards inside of it. With new panel installation, we would replace current grounding and bonding in the home by running new bare ground wire from utility room to the panel, installing new ground rods, installing new whole home emergency disconnect which is required by county, and a whole home surge protector to further assist in protection of the electrical panel and the home appliances. Comes with all materials, permits, inspections by county and organizing BGE. Due to age and integrity of devices in home a whole home re-device has been recommended to bring new life to old hazardous outlets and also add GFCI protection where it is required. Installation of (8) new recess lighting located in the living room. The installation comes with Pico and Casetta dimmers for the living room and dining room. Excludes patching and painting.
Elkridge, MD 21075
Michael W.
This solution includes the installation of a new switch in kitchen. Lastly this solution includes a new 100A panel and updated grounding.
Elkridge, MD 21075
dennis@haasandsons.com
The reason for today’s visit was to quote the home owner on replacement of her panel and adding recess lighting located in the dining room and living room. When meeting customer, i was then shown the areas where she would like the new lights to be installed. After viewing the rooms i began my assessment where her and i walked through the home and began to discuss things the inspector pointed out. All devices in the home were old and outdated and had zero integrity left. Multiple outlets showed “reverse polarity” and most outlets did not have proper GFCI protection. After viewing the devices customer showed me where her panel was located. The panel was a 200 amp split bus Sylvania panel with multiple issues. The panel was original to the home and I recommended to the customer that it should be replaced. After viewing the panel the customer and I began talking about her options or repairs/replacements. Customers husband is military so i did provide quotes with that discount showing. All
Elkridge, MD 21075
Alex W.
The customer originally called due to a lamp post light out front that was damage resulting in the circuit tripping. When i got to the home i saw a pvc pipe coming out front to the lamp post so i went into the basement to find the wire. The customers request was to turn that wire that went to the lamp post into a receptacle at the front of the home so they could plug in low-voltage lighting so while I was in the basement I wanted to make sure that the panels were safe so we can perform the work customer has a 400 amp service with two 200 amp Cutler hammer panels but I did notice that there was no surge protection other than that the panels were in great condition and so was the SEU cable from the meter into the panels themselves are brought up the surge protection to the customer and he thought that would be a good idea to install to protect his homes electronics and homes utilities from potential power surges. While we were out front talking about the pricing the customers also brou
Elkridge, MD 21075
Michael W.
This solution includes the installation of a new switch in kitchen. We have replaced the existing damaged switches inside the kitchen. We highly recommend having the Federal Pacific panel replaced.
Elkridge, MD 21075
Nicholas T.
Provided pricing to remove and replace for customer supplied lights on the front of the home.
Elkridge, MD 21075
Michael W.
This solution includes 3 dedicated 120V circuits to be installed in the crawl space for use of sump pump equipment and dehumidifier equipment.
Elkridge, MD 21075
Michael W.
We have delivered pricing regarding the crawl space dedicated circuits.
Elkridge, MD 21075
Review
dennis@haasandsons.com
Installation of new light switch located next to garage door that caused power loss issues to the bathroom lighting and garage lighting.
Elkridge, MD 21075
Genny G.
Today’s visit was for installing ring doorbell. While doing my assessment, I saw panel was extremely old and needs replacing. Please see solution for getting this resolved for you. Work performed today: Replace doorbell with Ring Replace doorbell transformer
Elkridge, MD 21075
Nicholas T.
Replaced bad breaker feeding kitchen appliance circuit. We installed a new 20 amp Eaton BR Deul function breaker. Once installed, we tested out the circuit and which it is now running fine..
Elkridge, MD 21075
Michael W.
This solution includes the wiring repair to the existing dimmer switch in the dining room and the replacement of the existing receptacle in the family room. We have replaced the existing receptacle in the family room. In addition we replaced the switch in the dining room. We recommend that a dedicated circuit be installed for all space heater use and maintenance to the main panel should be performed.
Elkridge, MD 21075
Alex W.
I removed and replaced the Wall receptacles in the living room I also removed and replaced a damaged dining room receptacle and a damaged receptacle in the upstairs bedroom I supposed all appropriate wires together and then pigtailed office place then hooked my single wire on the device screw clamped it then tighten down the screw this is to ensure the best possible connection throughout the electrical circuit I also re-wire the GFCI in the utility room so that if it tripped again it will not affect the living room circuit
Elkridge, MD 21075
Nicholas T.
Provided estimates to replace lightbulbs, Track lighting heads as well as custom split smoke detectors.
Elkridge, MD 21075
Michael W.
This solution includes the installation of a customer supplied exterior light for the back porch. In addition we shall replace the 2 exterior receptacles and garage receptacle. This solution includes gfci receptacles at the exterior and garage locations. We have installed the new customer supplied exterior fixture. We have also replaced the exterior, garage and basement receptacle at panel. This circuit now has GFCI receptacle at every location. Lastly we recommend whole home surge protection. Estimates have been sent via email.
Elkridge, MD 21075
Review
Alex W.
customer had a leak in the 1st floor bathroom which leaked into the box for the receptacle causing the wires to be damaged and the inside of the receptacle to be affected which in result kept tripping the master bathroom gfci I removed all receptacles on bathroom circuit and spliced all appropriate wires together then pig tailed off the splice with a single wire making the best and safest possible connections throughout the circuit. Then i installed a gfci in each bathroom and line sided all the gfcis so if one trips it doesnt affect the others throughout the bathrooms in the home.
Elkridge, MD 21075