This estimate includes the installation of a dedicated 40A 240V circuit to terminate on a receptacle for EV charging in the garage. Receptacle shall be protected by GFCI breaker We have installed a dedicated 240V 40A circuit for EV charging. Circuit terminated onto a 50A receptacle.
This estimate includes the replacement of the 2 hardwired antiquated smoke alarms with new combo detection alarms.
We have provided pricing for the replacement combo detection units and to bring the home up to code regarding the smoke alarms.
Service charge
We have determined the fan is working, issue was with remote.
Reason for today’s visit restore power loss to GFCI and utility closet in the garage as well as to troubleshoot a switch control in the exhaust fan in the second floor hallway bathroom. I started my troubleshooting at the basement GFCI in the utility room I found power going through the device but not leaving it. I then went to the main panel to check for any type of loose tucked loose connections or any signs of burning or fail devices which could cause connection issues. Well in the panel I found no signs of corrosion burning or anything that could cause power loss issues. I did however find that there was no surge protection at the main power source. The search protectors help prevent homes electrical system and equipment from being damage from harmful voltage spikes. I then proceeded to go to the second floor to check the switches in the hallway bathroom. I found that the switch control in the bathroom exhaust fan is a smart switch. The switch has a built-in humidity sensor that
Installing light in loft. #review
-Installed new security cameras with hard wired plugs on the front, back and right side of the house -Mount wireless ring doorbell on the front door -Run wires to the 3 cameras on the front, back and right side to eliminate the need to change batteries for those hard to reach cameras -install new grounding and bonding for hot & cold water along with gas -install 3 new receptacles where the loose ones where found in the home -install new gfci receptacle in bathroom upstairs -install new gfci receptacles in the kitchen and laundry room -move kitchen light and install recess light 4 inch. -replace improper breakers in the panel 4 total
Install car charger in garage next to panel.
We have installed new whole home surge protectors, 2 in total. In addition we have repaired the basement stairwell, foyer and dining area switches. We have also properly landed the ground wire from the service cable in the panel lug for the main panel to the right, as two strands of the aluminum were not landed under lug. We have also found no apparent power issues within the home regarding surging voltages.
We have installed new gfci receptacles in the bathrooms and the garage
I removed and replaced two switches in the hallway bathroom and respliced a bedroom fan in the master bedroom
Remove and replace 15 amp BR arc fault breaker with new This is not a permit fix. It’s my professional opinion the back stabbed outlets are still a high cause of the issue for this problem The circuit was holding after i installed the new arc fault breaker But the smoke alarms were chirping and the customer said they would take care of it 30 day warranty for the breaker
Customer called about ceiling fans Customer has a newer home with pre wired locations with ceiling fan boxes and 14-3 wire running to them from the switches I installed 4 customer supplied ceiling fans 1 for every bedroom upstairs and 1 for the living room downstairs 3 of the fans were remotes 1 was a pull chain and I installed a in wall switch controller for the customer in the office room upstairs I also removed the switches that weren’t being used and installed blank switches then put the switch plates back on Customer has a 30 day labor warranty
Run new dedicated #6 line from panel to Nema 15-50 receptacle on corner of the house. Run conduit from junction box to Nema 14-50R outdoor rated enclosure. Install new 40amp breaker for Nema 14-50 receptacle. Remove old 20amp breaker from panel.
I re fed a receptacle in the garage for the garage door and the internet from a keyless light fixture that was gfci protected in the utility room
Install new GfCIs in garage locations. Install new GFCI weather resistant receptacle and bubble cover outside. Rewired outside GFCIs to be operated independently. Rewired back stabbed outlet for garage door. Checked and tighten all connections in panel. 18 month warranty.
This estimate includes the installation of a new customer supplied light fixture in the upstairs bedroom. Arc-fault protection included. In addition we shall wire the existing switched receptacle to be constantly hot. We have installed a new customer supplied fixture in the bedroom. In addition we have we have replaced the bedroom receptacles. When the Arc fault breaker comes in we shall return and install. We have returned and installed the two pole ArcFault breaker. This estimate includes the installation of 6 4inch lights in each area. Dimmer switches included as well as arc fault protection. This estimate includes the installation of 3 led 6inch lights We have installed 12 4inch recess lights in the dining and front room. In addition we have installed 3 6inch recess lights in the first floor hallway. Lastly we have provided Arc-fault protection for new lighting.
Hall light fixture on top floor has extensive water damage and needs to be replaced. The romex that was exposed to water also needs to be replaced. Quoted a new company supplied light fixture and fixing the damaged wire.
Customers gfci on the patio has gone bad. Red light is on indicating it is in tripped state but it will not reset. Verified proper voltage from the wires and replaced the faulty device. Verified proper operation of all completed work.
Customer could not screw globe on fan. Removed piece that was in the wrong spot and reinstalled globe. Provided quote for installing a bath fan with heater and a dedicated circuit for fan.
Customer had another faulty breaker in panel. Replaced it with a dual function 15 amp Eaton BR breaker. Also installed a whole home surge protector. Verified proper operation of all completed work.
Customers home inspector flagged missing ground on the CSST manifold in the utility room. We ran a new #6 copper ground wire from the main panel in the garage through the ceiling over to the utility room and installed a grounding clamp on the manifold. Manifold is now grounded to current code/ safety requirements.
Installed a new 120 volt 20 amp dedicated circuit from the main panel in the basement up to the kitchen and installed a new GFCI outlet and switch for a new garbage disposal. We installed a new 20 amp cutler hammer br/cl series combination arc-fault breaker to power the new circuit. We sleeved wire underneath the sink in liquid tight to protect wire. Once installed we tested out circuit and it is working properly and ready for disposal.
2 breakers in panel were tripping randomly when nothing was being used(night time). There is no signs of any wiring issues so problem is most likely faulty BR dual function breakers. Replaced both breakers with new style dual function breakers and power was restored. Breakers are for kitchen receptacles and basement/smokes.