Haas & Sons provides electrical services that includes electrical repair and installations for Edgewater, MD residents —from lighting fixtures to ceiling fan installation to breaker box replacement and surge protection.
Call us now at: (443) 396-2555 and see why your neighbors rely on us to deliver local electrical services at great value for a fair price in Edgewater, MD below.
Recent Jobs and Reviews in Edgewater, MD
Edgewater, MD at a glance
Haas & Sons Electric Inc. has completed 25 jobs in Edgewater, MD between March 2024 and May 2025.
The one customer review shown here is rated 5.0 out of 5.
The most recent job was on May 20, 2025.
Haas & Sons Electric Inc. has completed 20 jobs in Edgewater, MD in the last 12 months. The first job there was in June 2019.
Job Locations and Reviews
Replace bad gfci in kitchen Install keyless in bedroom
Removal of existing fan and installation of new Panasonic quiet type fan with insulated venting a new roof top vent out. Installation of push style timer switch for new fan Reason for today’s visit was to replace an existing bathroom exhaust fan in second-floor toilet room in the primary bathroom. Existing fan did not work and was on a standard switch. Original fan was also not vented outside of the home. Today we went ahead and installed a new Panasonic quiet, type fan and its place and installed a timer switch to control the fan. We also installed new insulated ductwork. We also installed a new gooseneck vent out on the roof between the two existing ones.
We were called out today to look at replacing three switches with customer supplied smart switches to control light and fan separately. Switches were not the correct type to control the light and fan separately. The fans already had remotes that were not working. We determined the fan remotes were not working due to dead batteries. We switched the batteries and the fans began working.
This solution includes the wiring diagnostics and repairs to the kitchen and foyer lighting. We have repaired the wiring to the kitchen fixture and have repaired the 3way switching for foyer and lower level. We recommend having surge protection installed at the main panel.
Installation of a new Whole Home Surge protector to further assist the home in protection of the sub panel from voltage spikes as well as protecting sensitive appliances. Surge Reflects lifetime warranty type B.
Provide a pricing to install a new receptacle in the garage, cutting a new customer supplied camera floodlight on the front of the home, and install vanity lights in the primary bathroom on the second floor.
Arrived at the home and explained what all the whole home inspection would entail, and then got started. The home has already been redeviced and had a panel change this year so it was in really good shape, which our inspection reflected. At the end when i went over the inspection, he mentioned he had some other work he was interested in so i ended up writing it up for him and then we completed the following. Removed and replaced the kitchen sink light with a new one, although the bottom bracket that holds the glass was missing one piece from Home Depot so i discused how to get ahold of that one piece, and left the glass bottom off for now until he gets it. The other thing was adding a dedicated washer receptacle so the cord doesn’t stretch so far. I added a new 120v 20 amp line from the panel to a 1900 box i mounted on the wall where he specified, and installed a TR GFCI in the box. I tied in the feed and installed and labeled the new 20 amp leviton breaker.
Reason for the call was for annual maintenance service. Checked entire house from top to bottom. Everything is in good condition. I do recommend adding an additional surge for other panel for optimal protection. Customer also would like a dedicated circuit for hot tub. We performed the work for hot tub today.
Installation of a junction box below kitchen counter top to extend wires to sink base for a dishwasher appliance cord to be plugged in. Currently appliance has its own dedicated circuit and only needs a GFCI under the sink base to supply power. Dishwasher currently has a dedicated circuit that no longer has a neutral load in it. After we did previous work and finalized into testing the device, it only showed 40 amps at the device. We would run a new 20 amp dedicated circuit from the junction box to the dishwasher disconnect.
Installation of new devices through out the first floor of home to replace current original devices. Installation of new 200 amp Square D panel to eliminate current out dated/over heating 150 Square D panel. Panel currently has over heating on the bus bar, double tapped neutrals and grounds, shared branch circuits, and many unterminated wires hanging loose in panel. With new panel, we would update current grounding and bonding alongside adding two ground rods to the home and reattaching the whole home surge protector. Exterior disconnect would also be installed to give an added required means of disconnect in case of emergency for the home electrical system. Install new 10 year sealed google nest detectors throughout home to meet safety requirements.
Replace electrical panel. Update grounding and bonding for home. Re-Device the whole home. Add whole home surge protection to the new panel. RR 2 broken outlets in bedrooms.
Replace 2 outlets in upstairs bedroom that are completely broken.
Today’s visit was for breaker tripping to outside receptacle for waterfall. During investigation, I saw that the permit post was halfway buried under the flower bed and the receptacle was halfway filled with dirt. I also recommended replacing a dual function breaker to prevent any more intermittent tripping. I noticed that the subpanel did not have search protection so I recommended that as well. Please see below for work performed. Replace dual function breaker in sub panel Raise post in flower bed Replace WR receptacle in flower bed Install surge in sub panel for added protection
Arrived onsite and was shown the chandelier the customer wanted hung, and the situation with the ceiling that needed to be worked out in order to get it hung. I worked up a solution, and then assembled the light. In terms of height, it already hung pretty low so we decided on 5 links and that’s what I went with. I drilled out the center of the box for the allthread, connected it up with 3” heavy duty thread screws and then finished unwrapping the chandelier, installed the bulbs, tested and verified it working.
This solution includes the installation of the under cabinet lights. We have reinstalled the under cabinet lights in kitchen.
This solution includes the installation of 3 under cabinet lights and the creation of a new switch for lights
We installed new SEU cable rated for 200 A at the mast then down the mast after installing a new weatherhead over to the electrical meter then we removed the SEU cable from the panel to the meter and installed a new 200 amp SEU cable I remove the existing 150 amp electrical panel and installed a new 42 space 200 amp main breaker electrical panel with all new standard breakers then I landed all the wires in the Panel. And labeled the panel. I also had to shorten a 1 inch piece of conduit and installed a 1900 box that installed seal tight to run The existing wiring back into the electrical panel we had to do this because the pipe was going into the bottom the old panel but the newer panel is much larger so it was not lining up properly. We also installed a whole home surge protector to protect the homes electronics and the homes utilities from potential surges and we also ran a 12 three wire from the main electrical panel outside over to the customers bedroom on the other side of the ho
i installed a customer supplied light fixture on back upper porch I installed 2 customer supplied 120 volt landscape spot lights Also talked to customer about smart switches for 1st floor
Today’s visit was for front porch light not working. Turned out to be the switch. Work performed: Replace (1) toggle switch for front door
We have delivered pricing regarding the EV Circuit.
I installed 16 customer supplied lights 2 in the downstairs bathroom 1 in the upstairs hallway bathroom 13 outside throughout the yard and against the home exterior walls
Today’s visit was for exterior receptacles not working. During assessment, I located the bad GFCI in the utility room of the garage where the water heater was located. Also, the outdoor receptacles were highly corroded which most likely caused the GFCI to trip initially. Please see below for work performed to resolve the issue. Good luck with the move! Replace (1) indoor TR GFCI receptacle and cover. Replace (3) WR duplex receptacles and in use covers Replace (1) duplex receptacle in garage
This solution includes the replacement of the damaged GFCI at sink. Also, we shall replace the receptacle at the front door with a new weather rated device. We have replaced the gfci receptacle at the front door exterior and the gfci receptacle located in the secondary home at the sink location. Membership acquired.
Installation of two new carbon monoxide/smoke detectors located on the first floor and the second floor hall. Installation of new smoke detector located in the primary bedroom, secondary bedroom, and guest bedroom. Installation of new dedicated circuit located in the “pier shed” for a Mini-Fridge. Current circuit is being over-loaded when compressor kicks in and causing a trip on the GFCI.
Today’s visit was for ceiling fan replacement. While assessing the work to be done, I saw that there was no GFCI protection in the kitchen, and also no surge protection in the panel. See below for work performed. Remove and replace (1) ceiling fan Remove and replace (1) standard switch Install surge in main panel Install GFCI in kitchen to protect circuit
Took the time to give good information about how the equipment worked.