Haas & Sons provides electrical services that includes electrical repair and installations for Glenwood, MD residents —from lighting fixtures to ceiling fan installation to breaker box replacement and surge protection. Call us now at: (443) 396-2555 and see why your neighbors rely on us to deliver local electrical services at great value for a fair price in Glenwood, MD below.

Recent Jobs and Reviews in Glenwood, MD

Rated 5.0 out of 5 stars based on 2 customer reviews

Customers say: The reviews reflect an overwhelmingly positive sentiment toward the electrical service provided. Customers consistently express high satisfaction with the technicians' professionalism, knowledge, and communication skills. The reviews highlight how well the electricians explained their work, answered questions patiently, and ensured customer satisfaction with the final results. There's a recurring theme of appreciation for the technicians' problem-solving abilities and their friendly, patient demeanor. Customers also value the efficiency of service, with work being completed as scheduled and sometimes even more quickly than expected. The overall tone is decidedly positive, with multiple mentions of customers feeling confident in the quality of work performed and expressing intentions for continued patronage. The service team appears to consistently exceed expectations, demonstrating technical expertise while maintaining excellent customer relations.

Job Locations and Reviews

For today’s visit was for recess lights in 2 rooms, the office and the downstairs bedroom. We also checked the panel and found a lack of surge protection and 1 arc fault breaker that was going bad, so we replaced that and installed a surge vortex in the panel on a BR 50 amp breaker. The downstairs bedroom we installed 4 - 6 inch recess lights with a cassetta smart switches. Then we started work in the office and cut 3 recess holes, but they had LVL joists where 2 of our recess lights were. So they couldn’t fit, even if we did 6 inch recess lights. The only way to make it work were to make the 2 recess lights offset closer to the middle of the room, which would give the fan a strobe effect and not look good. We discussed to the customer and decided not to do the work in the office, so we put the drywall patches back, and took the money off the ticket.
For today’s visit was for recess lights in 2 rooms, the office and the downstairs bedroom. We also checked the panel and found a lack of surge protection and 1 arc fault breaker that was going bad, so we replaced that and installed a surge vortex in the panel on a BR 50 amp breaker. The downstairs bedroom we installed 4 - 6 inch recess lights with a cassetta smart switches. Then we started work in the office and cut 3 recess holes, but they had LVL joists where 2 of our recess lights were. So they couldn’t fit, even if we did 6 inch recess lights. The only way to make it work were to make the 2 recess lights offset closer to the middle of the room, which would give the fan a strobe effect and not look good. We discussed to the customer and decided not to do the work in the office, so we put the drywall patches back, and took the money off the ticket.
Dennis S.
Dennis S. Checked in
For today’s visit was for recess lights in 2 rooms, the office and the downstairs bedroom. We also checked the panel and found a lack of surge protection and 1 arc fault breaker that was going bad, so we replaced that and installed a surge vortex in the panel on a BR 50 amp breaker. The downstairs bedroom we installed 4 - 6 inch recess lights with a cassetta smart switches. Then we started work in the office and cut 3 recess holes, but they had LVL joists where 2 of our recess lights were. So they couldn’t fit, even if we did 6 inch recess lights. The only way to make it work were to make the 2 recess lights offset closer to the middle of the room, which would give the fan a strobe effect and not look good. We discussed to the customer and decided not to do the work in the office, so we put the drywall patches back, and took the money off the ticket.
Glenwood, MD 21738
Replace 2 first generation Siemens arc fault breaker controlling bedrooms.
Replace three improper breakers, including an art fault that was removed and sometime in the past, then illegally replaced with a standard breaker.
Return today and completed quoted Work. We replaced the two existing arc fault breakers that were the first generation that we’re going bad as well as installed in arc fall breaker back went to the master bedroom that somebody had removed in the past. We also replaced the tandem breaker on the left side of the panel that did not match the brand as well as the bottom right 20 amp breaker that was not the proper one as well. 
All the breakers in this left panel now match the brand.
Replace 2 first generation Siemens arc fault breaker controlling bedrooms.
Replace three improper breakers, including an art fault that was removed and sometime in the past, then illegally replaced with a standard breaker.
Return today and completed quoted Work. We replaced the two existing arc fault breakers that were the first generation that we’re going bad as well as installed in arc fall breaker back went to the master bedroom that somebody had removed in the past. We also replaced the tandem breaker on the left side of the panel that did not match the brand as well as the bottom right 20 amp breaker that was not the proper one as well. 
All the breakers in this left panel now match the brand.
Nicholas T.
Nicholas T. Checked in
Replace 2 first generation Siemens arc fault breaker controlling bedrooms. Replace three improper breakers, including an art fault that was removed and sometime in the past, then illegally replaced with a standard breaker. Return today and completed quoted Work. We replaced the two existing arc fault breakers that were the first generation that we’re going bad as well as installed in arc fall breaker back went to the master bedroom that somebody had removed in the past. We also replaced the tandem breaker on the left side of the panel that did not match the brand as well as the bottom right 20 amp breaker that was not the proper one as well. All the breakers in this left panel now match the brand.
Glenwood, MD 21738
Review
Nick was incredibly professional. Very personable and respected the house by cleaning up after the work was completed.
Tom - Glenwood, MD 21738
Nicholas T.
Nicholas T. Checked in
Replace ceiling, fan and chandelier in one go on a return trip Reason for today’s visit was to look at replacing a chandelier in the dining area as well as a ceiling fan in the family room. The chandelier is on but appears to be an 1819 foot vaulted ceiling and the ceiling fan is on what appears to be a 15 foot ceilings. We will need a tall ladder to install these two fixtures. When inspecting the chandelier for the dining area, we found out that the light was only about 6 foot long in which they needed a much longer fixture hanging from a chain. Customer is going to find a new chandelier and contact us back to install both fixtures at the same time
Glenwood, MD 21738
josh@haasandsons.com
josh@haasandsons.com Checked in
Reason for today’s visit with the customer was a tripped GFCI located at the panel. Upon investigation I discovered the two outdoor receptacles were allowing water to get trapped inside of them which lead to the GFCI Tripping. To remedy this I recommended to replace the outdoor receptacles and bubble covers, replace the panel GFCI with a receptacle, and finally land the circuit on a Dual-Function Breaker. The customer agreed and the work was completed. Today the customer also activated their 1 Year VIP Membership with us. Upon departure all work was complete and operating as intended.
Glenwood, MD 21738
Michael W.
Michael W. Checked in
This solution includes the installation of a gfci receptacle Under sink to power garbage disposal, shall be wired to existing switch. In addition we shall replace the hall bathfan and switch, properly install led bypass tubes for the laundry light and basement lights, replace the keyless fixture in mechanical room and replace the work area light with a new customer supplied fixture. We have replaced the existing bath fan in hall bathroom, repaired 4 fluorescent lights replacing them with led bypass tubes, installed gfci for garbage disposal and installed the customer supplied fixture and keyless fixture in mechanical room.
Glenwood, MD 21738
Michael W.
Michael W. Checked in
This solution includes the basic repair for the exterior receptacles. We shall replace the existing devices at front and rear of home, 2 total. In addition we shall install a GFCI receptacle at garage entrance. We have installed new weather rated devices on the front exterior and rear exterior of home. In addition we have installed a new GFCI receptacle at garage entrance.
Glenwood, MD 21738
Nicholas T.
Nicholas T. Checked in
Replace exhaust fan in bathroom with customer supplied EF Replace (2) 1x4 strip fixtures Replace existing service with 400 amp service. Added (2) emergency service disconnects.
Glenwood, MD 21738
Matt M.
Matt M. Checked in
Replace foyer light Replace ceiling fan in the sunroom
Glenwood, MD 21738
Nicholas T.
Nicholas T. Checked in
WO-TNFR79534 Replaced customer supplied through the roof attic fan motor and thermostat. Tested power and it works properly. I set thermostat to 100 degrees.
Glenwood, MD 21738
Review
Excellent Employee
Bill - Glenwood, MD 21738
Michael W.
Michael W. Checked in
This estimate includes the installation of 2 new LED closet lights for the bedroom. We shall supply the Hard wired closet lights. We have returned and installed new closet lighting. New lights are LED and operate from the existing switch.
Glenwood, MD 21738
Michael W.
Michael W. Checked in
This estimate includes the installation of a dedicated 240V 50A circuit for the cooktop. This estimate includes the installation of 20A GFCi receptacle We have installed a new dedicated circuit for the cooktop. In addition we have installed a new 20A gfci receptacle in the basement. We shall return to install the 50A breaker for cooktop next Wednesday. We have returned and installed the correct 240V 50A breaker for the cooktop. Lastly, we have labeled the cooktop in the main panel.
Glenwood, MD 21738
Nicholas T.
Nicholas T. Checked in
Installed ceiling fans in 2 2nd floor bedrooms.
Glenwood, MD 21738
Nicholas T.
Nicholas T. Checked in
Replaced burnt out outlet in master bath.
Glenwood, MD 21738

Taking the Best Care of Our Customers

Upfront Pricing Always

Anne Arundel, Howard & Montgomery Counties' premier electrician. Providing local homeowners with cost effective safe, and professional electrical services.

Request Service
servicedetailscustomerreturningschedule
*
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
Select your preferred date to view available times

Call For Same Day Service/Emergencies at 443.396.2555 .

Consent for Calls
By clicking "Yes" you provide express written consent indicating a willingness for us to call you. We will never share your information.Privacy Policy / TOS
Consent for SMS
By clicking "Yes" you provide express written consent to contact you via SMS no more than 2-4 times / month. Standard messaging and data rates apply. Text STOP to opt-out at anytime.Privacy Policy / TOS
Back Next