Haas & Sons provides electrical services that includes electrical repair and installations for Hyattsville, MD residents and businesses—from lighting fixtures to ceiling fan installation to breaker box replacement and surge protection. Call us now at: (443) 396-2555 and see why your neighbors rely on us to deliver local electrical services at great value for a fair price in Hyattsville, MD below.
Recent Jobs and Reviews in Hyattsville, MD
Job Locations and Reviews
josh@haasandsons.com
Arrived onsite and took a look at all the projects she wanted to get done from recess in the dining room, to the ceiling fans they wanted in each of the bedrooms upstairs, as well as removing one recess on the wrap around porch, putting a barbox in and converting it to a ceiling fan. As i was walking around doing my performance and safety assessment i found a number of things i went over with her, helped her understand, and then wrote an estimate to address as well from redevicing the entire home, to adding bonding at the hot water heater, to adding whole home surge protection at the main panel. They will call in and let us know what they would like done.
Hyattsville, MD 20781
dennis@haasandsons.com
Replace customer supplied lamps- 13 in total. No warranty Installation of new 18 inch under cabinet LED fixture for the closet. Customer supplied.
Hyattsville, MD 20782
Review
Genny G.
Today’s visit was for annual maintenance inspection. During assessment, I saw a few things of note that needed to be addressed. Customers panel was just replaced and solar installed. Panel is already starting to show signs of rust at the bottom. I believe the moisture barrier should be replaced. Also, the panel was labeled incorrectly. I corrected the circuits I worked on. The customer is having the solar company come out to address the other issues. While on-site, I saw sump pumps and washer were not GFCI protected, there was a receptacle upstairs that had an open ground, and no surge protection present. Please see below for work performed. Install audible GFCIs for both sump pumps Install standard GFCI for washer Install standard GFCI for open ground receptacle Install whole home surge in main panel
Hyattsville, MD 20782
Michael W.
Pricing has been delivered regarding the heavy up.
Hyattsville, MD 20782
Nicholas T.
The reason for today’s visit was to assess power loss to the garage, laundry, room, lights, and the living room Receptacles. No troubleshooting, we begin unplugging devices and turning switches off. Reset the breaker and the power was restored. We went through and turned everything back on until we got to the switch that went to the post light, which is located in the front right corner of the garage, we took the wires and found that there was continuity neutral And the hotwire. When we took apart the post light, we found that the wires were cut extremely short into the bottom of the post, and there was no post headlight on it whatsoever. The customer decided to cut the wires off and disconnect the post so power could be restored. Troubleshooting, we did notice that the panels were older 1983 Bryant panels with several different types of breakers mismatched inside. Many of the breakers are difficult to turn off and turn back on indicating it is time for them to be replaced. Due to the
Hyattsville, MD 20782
dennis@haasandsons.com
Installation of new 3 prong drier device to replace broken and outdated appliance receptacle that no longer works properly.
Hyattsville, MD 20783
Michael W.
This solution includes the installation of 4 customer supplied light fixtures and the replacement of a dimmer switch. We have replaced the light fixtures in the foyer, 2nd floor landing, pantry and closet area. New dimmer switch installed too.
Hyattsville, MD 20782
dennis@haasandsons.com
Installation of two new outdoor fixture rated boxes for sub-basement closet where customer would like to have a new switch to control the current pull chain light fixtures. Fixtures are currently have power fed by way of old rusted conduit where as new installation would be ran in UF due to area having heavy moisture. With installation of new boxes and new switch, adding two new non-pull chain keyless fixture mounts to go on those boxes. Installation of new 15 amp homeline breaker due to current breaker showing signs of failure and over heating. Replacement of current neutral shared circuit with required 2-pole breaker in sub panel.
Hyattsville, MD 20782
Alex W.
Service charge
Hyattsville, MD 20782
Matt M.
Run a dedicated line to the hot tub with disconnect and piping to the hottub
Hyattsville, MD 20784
Alex W.
I removed and replaced the receptacle in the entertainment center that was Energized by circuit 19 in the main electrical panel the receptacle had a wire that had a cut in it due to poor installation in the receptacle in the wire was pinched which was hitting the metal box causing it to ground out I Cut out the damage wire then I spliced all the appropriate wires together and pigtail office splice then hooked the single wire on the new receptacle clamp the wire down then Tightened the screw on the device. This is to ensure the best possible connection and the safest possible connection in the termination for the receptacle
Hyattsville, MD 20782
Matt M.
As a result of the fire we will have to replace the panel with a new unit along with the meter can and service cable coming from the meter and overhead down to the meter and run new ground wire to the main water and install binding for the electrical system of the home. We will replace all breakers and Eliminate burnt wires from the wall and panel and run new ones
Hyattsville, MD 20784
Review
Matt M.
Cleaned out post light
Hyattsville, MD 20782
Alex W.
Service charge
Hyattsville, MD 20782
Genny G.
Replace switch and receptacles not working. Secure box hanging underneath sink.
Hyattsville, MD 20781
Nicholas T.
Reason for today’s visit was to replace the bedroom ceiling fan in the back left corner on the top floor with a new customer supplied fan. Van already had a metal fan rated box in place. While on site we also replaced customer supplied exterior wall sconces light at the back door.
Hyattsville, MD 20782
Review
Nicholas T.
We will remove and replace the 2nd floor hallway light with a new customer supplied chandelier We will replace customer supplied bathroom vanity light in 1st floor office. We will install a new receptacle in the front sitting room side wall.
Hyattsville, MD 20782
Alex W.
I removed and replaced a bathroom light switch in the master bathroom that was burnt and I installed a whole home surge protector in the main electrical panel in the basement 1 year warranty
Hyattsville, MD 20782
Michael W.
We have installed a new electrical box and keyless light fixture in the laundry area. In addition we have installed a new customer supplied chandelier in the dining room.
Hyattsville, MD 20782
Nicholas T.
Customer lost power to the living room receptacles as well as the basement lighting circuit. We found that both breakers feeding those circuits were tripping off. After further investigation we found that the 3-way at the top of the basement stairs was shorting out the circuit when any of the 3 switches were turned on. We also found that the metal connector in the receptacle box in the left corner of the living was cutting into the hot wire causing the breaker to trip. While checking the wiring in lights and devices we found that the insulation around the wires are falling to pieces leaving exposed conductors. Recommend re-wiring of branch circuits to prevent further issues. We replaced the broken 3-way switch at the top of the stairs and taped up the bare wires as good as possible. We replaced the damaged receptacle in the living room exterior wall to the left of the window and taped up the wires as good as possible.
Hyattsville, MD 20782
Nicholas T.
Customer had issues with the GFCI for the pond equipment tripping. We found that the box was allowing water inside and causing it to trip every time it water gets on the box. We removed the box and the old wooden post and installed a new permanent post with 2 new weather resistant GFCI devices and 2 new in-use covers. Once installed we tested outlets and pond pump and everything works as it should.
Hyattsville, MD 20782
Michael W.
WO-TNFR81241 We have replaced the existing damaged switch controlling the dining room chandelier. Original call was damaged switch, light not turning off.
Hyattsville, MD 20782
Michael W.
WO-TNFR79013 We have restored power to the pool house GFCI. Receptacle was tripping when switch on the right was engaged. We have removed damaged wire from switch.
Hyattsville, MD 20781
Review
Matt M.
Replaced broken recess lights in basement.(EC6A) Replaced outlet box sticking out of wall.(EG1A)
Hyattsville, MD 20782
Review
Review
Review