Haas & Sons provides electrical services that includes electrical repair and installations for Hyattsville, MD residents —from lighting fixtures to ceiling fan installation to breaker box replacement and surge protection. Call us now at: (443) 396-2555 and see why your neighbors rely on us to deliver local electrical services at great value for a fair price in Hyattsville, MD below.
Recent Jobs and Reviews in Hyattsville, MD
Job Locations and Reviews
josh@haasandsons.com
Arrived onsite and was shown to the downstairs bathroom where I opened the exhaust fan that was there, cleaned it all out and then talked to the resident about what they wanted to do with that one. The preference downstairs is to get the same model nutone and replace what’s there because it fits the space and will minimize plaster damage. For the upstairs bathroom there is no attic space, and I don’t think the ceiling is tall enough there to put the fan in the ceiling, but there is a side attic that backs up to that bathroom so I made a whole plan to install a wall fan and do all the ducting and wiring in the attic space to minimize the plaster damage, and we would install a Panasonic whisper in the space. The resident wants to cut the ceiling open and see the clearance there to see if it’s a possibility, and he’s fine with the plaster damage upstairs if the fan fits the ceiling. I wrote up multiple options, but he wants to look into the space upstairs before deciding which one he wou
Hyattsville, MD 20782
josh@haasandsons.com
Arrived onsite and the resident explained how her smoke detectors were out of date and most are beeping currently. I went and took a full count and wrote up the option to take care of all of them today, as well as our membership package and she ended up getting both. We removed and installed all of the new smoke detectors, tested and are working properly. We cleaned up and then i wrote it up for her.
Hyattsville, MD 20781
Nicholas T.
The reason for today’s visit was to assess microwave that was tripping the breaker. When we arrived, we attempted turning the microwave on to get the problem to happen again however it never did. We ran the microwave multiple times for minutes at a time and it was running properly. We checked terminations and everything looked good. We even attempted to use a heat gun in the microwave circuit to see if we could simulate the issue and we’re unable to do so. We recommended installation of whole home service protection the main panel as the home does not have any, and we also recommended a replacement of the arc fall breaker as a possible prevention option. Whole Home Surge Protection is designed for Main panel, subpanel, and point-of-use applications up to 200 KAIC fault current rating. Status LED with an audible alarm. 120kA available in all single and three phase. NEMA 4X (IP65/IP66) indoor/outdoor rated enclosure.
Hyattsville, MD 20782
Genny G.
Today’s visit was for installing pendant lights in the kitchen, which totaled four altogether. We had also missed devices from when we were here prior that needed to be replaced. They were hidden behind picture frame. Let us know if you need anything else. Thank you! Replace (4) pendant light fixtures in kitchen
Hyattsville, MD 20782
Nicholas T.
Heavy up of 400 amp service upgrade Remove and replace all switches and receptacles throughout home Install nest smoke detector on each floor Friday, 22nd Nov. Completed first floor redevice (Bedroom, office, living room, kitchen, mud room, sun room). Will redevice outside receptacles, as well as finish dining room redevice on Monday. Circuit repair will need to be done on switch controlling mud room bathroom and switch in dining room. Will complete heavy up on Monday. Monday, 25th Nov. Completed installation of two Leviton 200 amp panels with 2 Vortexx surge protectors. Installed 400 amp meter. Ran both 4/0 service cables in parallel to meter. Installed 5 Google Nest smoke/CO detectors throughout home. Replaced remaining devices that were missed. Installed Caseta Pico switch in dining room to repair circuit, as well as repaired switch to bathroom in mud room. Ready for inspection.
Hyattsville, MD 20782
josh@haasandsons.com
Arrived onsite and took a look at all the projects she wanted to get done from recess in the dining room, to the ceiling fans they wanted in each of the bedrooms upstairs, as well as removing one recess on the wrap around porch, putting a barbox in and converting it to a ceiling fan. As i was walking around doing my performance and safety assessment i found a number of things i went over with her, helped her understand, and then wrote an estimate to address as well from redevicing the entire home, to adding bonding at the hot water heater, to adding whole home surge protection at the main panel. They will call in and let us know what they would like done.
Hyattsville, MD 20781
dennis@haasandsons.com
Replace customer supplied lamps- 13 in total. No warranty Installation of new 18 inch under cabinet LED fixture for the closet. Customer supplied.
Hyattsville, MD 20782
Review
Genny G.
Today’s visit was for annual maintenance inspection. During assessment, I saw a few things of note that needed to be addressed. Customers panel was just replaced and solar installed. Panel is already starting to show signs of rust at the bottom. I believe the moisture barrier should be replaced. Also, the panel was labeled incorrectly. I corrected the circuits I worked on. The customer is having the solar company come out to address the other issues. While on-site, I saw sump pumps and washer were not GFCI protected, there was a receptacle upstairs that had an open ground, and no surge protection present. Please see below for work performed. Install audible GFCIs for both sump pumps Install standard GFCI for washer Install standard GFCI for open ground receptacle Install whole home surge in main panel
Hyattsville, MD 20782
Michael W.
Pricing has been delivered regarding the heavy up.
Hyattsville, MD 20782
Nicholas T.
The reason for today’s visit was to assess power loss to the garage, laundry, room, lights, and the living room Receptacles. No troubleshooting, we begin unplugging devices and turning switches off. Reset the breaker and the power was restored. We went through and turned everything back on until we got to the switch that went to the post light, which is located in the front right corner of the garage, we took the wires and found that there was continuity neutral And the hotwire. When we took apart the post light, we found that the wires were cut extremely short into the bottom of the post, and there was no post headlight on it whatsoever. The customer decided to cut the wires off and disconnect the post so power could be restored. Troubleshooting, we did notice that the panels were older 1983 Bryant panels with several different types of breakers mismatched inside. Many of the breakers are difficult to turn off and turn back on indicating it is time for them to be replaced. Due to the
Hyattsville, MD 20782
dennis@haasandsons.com
Installation of new 3 prong drier device to replace broken and outdated appliance receptacle that no longer works properly.
Hyattsville, MD 20783
Michael W.
This solution includes the installation of 4 customer supplied light fixtures and the replacement of a dimmer switch. We have replaced the light fixtures in the foyer, 2nd floor landing, pantry and closet area. New dimmer switch installed too.
Hyattsville, MD 20782
dennis@haasandsons.com
Installation of two new outdoor fixture rated boxes for sub-basement closet where customer would like to have a new switch to control the current pull chain light fixtures. Fixtures are currently have power fed by way of old rusted conduit where as new installation would be ran in UF due to area having heavy moisture. With installation of new boxes and new switch, adding two new non-pull chain keyless fixture mounts to go on those boxes. Installation of new 15 amp homeline breaker due to current breaker showing signs of failure and over heating. Replacement of current neutral shared circuit with required 2-pole breaker in sub panel.
Hyattsville, MD 20782
Alex W.
Service charge
Hyattsville, MD 20782
Matt M.
Run a dedicated line to the hot tub with disconnect and piping to the hottub
Hyattsville, MD 20784
Alex W.
I removed and replaced the receptacle in the entertainment center that was Energized by circuit 19 in the main electrical panel the receptacle had a wire that had a cut in it due to poor installation in the receptacle in the wire was pinched which was hitting the metal box causing it to ground out I Cut out the damage wire then I spliced all the appropriate wires together and pigtail office splice then hooked the single wire on the new receptacle clamp the wire down then Tightened the screw on the device. This is to ensure the best possible connection and the safest possible connection in the termination for the receptacle
Hyattsville, MD 20782
Matt M.
As a result of the fire we will have to replace the panel with a new unit along with the meter can and service cable coming from the meter and overhead down to the meter and run new ground wire to the main water and install binding for the electrical system of the home. We will replace all breakers and Eliminate burnt wires from the wall and panel and run new ones
Hyattsville, MD 20784
Review
Matt M.
Cleaned out post light
Hyattsville, MD 20782
Alex W.
Service charge
Hyattsville, MD 20782
Genny G.
Replace switch and receptacles not working. Secure box hanging underneath sink.
Hyattsville, MD 20781
Nicholas T.
Reason for today’s visit was to replace the bedroom ceiling fan in the back left corner on the top floor with a new customer supplied fan. Van already had a metal fan rated box in place. While on site we also replaced customer supplied exterior wall sconces light at the back door.
Hyattsville, MD 20782
Review
Nicholas T.
We will remove and replace the 2nd floor hallway light with a new customer supplied chandelier We will replace customer supplied bathroom vanity light in 1st floor office. We will install a new receptacle in the front sitting room side wall.
Hyattsville, MD 20782
Alex W.
I removed and replaced a bathroom light switch in the master bathroom that was burnt and I installed a whole home surge protector in the main electrical panel in the basement 1 year warranty
Hyattsville, MD 20782
Michael W.
We have installed a new electrical box and keyless light fixture in the laundry area. In addition we have installed a new customer supplied chandelier in the dining room.
Hyattsville, MD 20782